Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endourol ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38429915

RESUMO

Urothelial carcinoma (UC) affecting the urinary tract is recognized as one of the prevalent types of cancer, ranking fifth in terms of incidence. However, it is important to note that upper tract urothelial carcinoma (UTUC), in comparison to bladder cancer, is relatively uncommon and represents a minority of UC cases, accounting for ∼5% to 10%. It is worth emphasizing that as much as 60% of UTUC cases are invasive at the time of diagnosis, in contrast to 25% of bladder cancer cases. These statistics highlight the urgent need for well-designed, multidisciplinary strategies to guide optimal management for this vulnerable patient population, aiming to control treatment variability and minimize the risks associated with undertreatment and overtreatment. Methods: In this study, we present a comparative analysis of the contemporary guidelines on UTUC management from the European Association of Urology (EAU) and the American Urological Association/Society of Urologic Oncology (AUA/SUO) released in 2023. Our objective is to contrast the different guidelines and examine the evidence on which their recommendations are based. Results: By thoroughly reviewing the guidelines from both organizations, we observed substantial agreement on the management of UTUC. However, we also identified noticeable differences among these guidelines, leading to a wide range of recommendations. These disparities might stem from variations in clinical practices, regional preferences, and the availability of resources. It is crucial to acknowledge that both the EAU and AUA/SUO base their guidelines on the latest scientific evidence and expert consensus within their respective regions. Conclusions: These findings underscore the importance of ongoing collaboration, knowledge exchange, and harmonization of guidelines to improve the standard of care for UTUC globally. Future research should focus on identifying areas of consensus and bridging the gaps between different international guidelines to enhance the management outcomes for this challenging disease.

2.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
4.
Eur Urol Focus ; 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37940392

RESUMO

CONTEXT: Laser performance for lithotripsy is currently reported using units of measurement such as J/mm3, mm3/J, mm3/s, s/mm3, and mm3/min. However, there are no current standardized definitions or terminology for these metrics. This may lead to confusion when assessing and comparing different laser systems. OBJECTIVE: The primary objective was to summarize outcome values and corresponding terminology from studies on laser lithotripsy performance using stone volume in relation to time or energy. The secondary objective was to propose a standardized terminology for reporting laser performance metrics. EVIDENCE ACQUISITION: A systematic review of the literature was conducted using the search string ("j*/mm3" OR "mm3/j*" OR "mm3/s*" OR "s*/mm3" OR "mm3/min*" OR "min*/mm3" AND "lithotripsy") on Scopus, Web of Science, Embase, and PubMed databases. Study selection, data extraction, and quality assessment were performed independently by two authors. EVIDENCE SYNTHESIS: A total of 28 studies were included, covering holmium:yttrium-aluminum-garnet (Ho:YAG), MOSES, and thulium fiber laser (TFL) technologies. Laser energy consumption values reported for the studies ranged from 2.0 - 43.5 J/mm3in vitro and from 2.7 - 47.8 J/mm3in vivo, translating to laser ablation efficiency of 0.023 - 0.500 mm3/J and 0.021 - 0.370 mm3/J, respectively. Laser ablation speeds ranged from 0.3 - 8.5 mm3/s in vivo, translating to lasing time consumption of 0.12 - 3.33 s/mm3. Laser efficacy ranged from 4.35 - 51.7 mm3/min in vivo. There was high heterogeneity for the terminology used to describe laser performance for the same metrics. CONCLUSIONS: The range of laser performance metric values relating stone volume to energy or time is wide, with corresponding differing terminology. We propose a standardized terminology for future studies on laser lithotripsy, including laser ablation efficiency (mm3/J), laser ablation speed (mm3/s), and laser energy consumption (J/mm3). Laser efficacy (mm3/min) is proposed as a broader term that is based on the total operative time, encompassing the whole technique using the laser. PATIENT SUMMARY: We reviewed studies to identify the units and terms used for laser performance when treating urinary stones. The review revealed a wide range of differing units, outcomes, and terms. Therefore, we propose a standardized terminology for future studies on laser stone treatment.

5.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831156

RESUMO

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Nefrolitíase , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Litotripsia a Laser/métodos , Cálculos Urinários/terapia , Oxalato de Cálcio , Hólmio
6.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37587366

RESUMO

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Poeira , Litotripsia a Laser/métodos , Cálculos Urinários/terapia
7.
Ther Adv Urol ; 15: 17562872231179332, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37377944

RESUMO

Objective: The objective of this study was to evaluate a new concept in flexible ureteroscopy: instrumental dead space (IDS). For this purpose, various proximal working channel connector designs, as well as the impact of ancillary devices occupying the working channel were evaluated in currently available flexible ureteroscopes. Design and methods: IDS was defined as the volume of saline irrigation needed to inject at the proximal connector for delivery at the distal working channel tip. Because IDS is related to working channel diameter and length, proximal connector design, as well as occupation of working channel by ancillary devices, these parameters were also reviewed. Results: IDS significantly varied between flexible ureteroscope models, ranging from 1.1 ml for the Pusen bare scopes, to 2.3 ml for Olympus scopes with their 4-way connector (p < 0.001). Proximal connector designs showed a high degree of variability in the number of available Luer locks, valves, seals, angles, and rotative characteristics. The measured length of the working channel of bare scopes ranged between 739 and 854 mm and significantly correlated with measured IDS (R2 = 0.82, p < 0.001). The coupling of scopes with an alternative ancillary proximal connector and the insertion of ancillary devices into the working channel significantly reduced IDS (mean IDS reduction of 0.1 to 0.5 ml; p < 0.001). Conclusions: IDS appears as a new parameter that should be considered for future applications of flexible ureteroscopes. A low IDS seems desirable for several clinical applications. The main factors impacting IDS are working channel and proximal connector design, as well as ancillary devices inserted into the working channel. Future studies should clarify how reducing IDS may affect irrigation flow, intrarenal pressure, and direct in-scope suction, as well as evaluate the most desirable proximal connector design properties.

9.
J Endourol Case Rep ; 5(2): 34-38, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31179381

RESUMO

Background: Polypoid cystitis is infrequently seen in noncatheterized patients, occasionally posing challenging treatment options. We present a rare case of polypoid cystitis with bilateral upper tract obstruction mimicking a bladder tumor, needing staged endoscopic management. Case Presentation: A 45-year-old Asian man with a bladder tumor presented with lower urinary tract symptoms. Subsequent transurethral resection of bladder tumor histology revealed polypoid cystitis. This had caused intramural edema and obstruction of the distal ureters that were managed with initial local resection, ureteral dilatation with a period of ureteral stenting, and oral steroids. Subsequent intravenous urogram and diuretic renogram showed resolution of obstruction and resolution of hydronephrosis. He also had mixed lower urinary tract symptoms and hematuria managed with combination of solifenacin, finasteride, and tamsulosin. Conclusion: Polypoid cystitis with ureteral obstruction needs to be considered in differentials of a bladder tumor, and management may include a combination of endoscopic resection, ureteral stenting, and in resistant cases oral steroids can be considered to aid resolution of inflammation in the absence of infection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...